AC Input:
BVS products automatically adjust to the input voltage as follows:
BVS30, 40, 60 and 80: wide range input from 90-264 VAC
DC Outputs:
See Voltage/Current Rating Charts.(Standard Models)
Output Power:
See Voltage/Current Rating Charts.(Standard Models)
Peak Output Power:
See Voltage/Current Rating Charts.(Standard Models)
Sixty second maximum peak power duration’s. A 10% duty
cycle is not to be exceeded when peak power duration’s
are combined.
Brown-Out Voltage:
Regulation is maintained with full rated load at 90 VAC
Hold-Up Time:
20 msec typical at full rated load and nominal AC input
voltage. Hold-up time increases to 40 msec at 50% load.
Power-Fail Warning Signal:
TTL compatible signal goes low before the main +5V output
drops 5%, at full rated load on BVS 80
Typical warning time:
BVS 80: 5 msec where applicable
Warning time increases at reduced load levels
Efficiency:
Measured at full rated load and nominal AC input voltage.
75% ±5% depending on how the load is distributed among
the outputs.
Regulation Characteristics:
See Voltage/Current Rating Charts for individual model ratings.
Measurement method:
Line: Measured over a 90-132 VAC or 175-264 VAC line change.
Load: Measured over a 20% to 100% load change. Multiple
output model regulation is subject to the minimum
load
requirements mentioned below.
Minimum Loads:
The following minimum loads are required to maintain regulation.
Multiple output models are expressed as current on
the main output.
Multiple output Single output
|   | Multiple Output | Single Output |
| BVS 80 | 1A | 5 Watts |
| BVS 40, 60 | 0.5A | 3 Watts |
Initial Setting Tolerance:
Measured at 50% of full rated load on all outputs.
Remote Sensing:
Optional on selected models only.
Output Noise and Ripple:
0.3% RMS, 1% PK-PK maximum on main +5V output.
Transient Response:
Main +5V output: 500 sec typical for a 50-100% load
change and recovery to within 1% of initial voltage set
point. Maximum excursion: 4% from initial voltage set point.
Overload Protection:
Fully protected against output overload and short circuit.
Automatic recovery upon removal of overload condition.
Delayed-foldback current limiting characteristics assure
reliable turn-on into reactive and non-linear loads.
Overvoltage Protection:
Provided on the main +5V output. Factory set at 6.2V±0.6V.
Power-Up Initialization Period:
Typical 2.0 sec turn-on delay assures orderly ramp-up and
stabilization of all output voltages during power-up.
Input Protection:
AC input line fuse provided. Internally located.
Inrush Current:
Internally limited by thermistor.
Temperature Rating:
Operating: 0°C to +50°C at full rated output power. Derate
linearly to 50% of full load from 50°C to 70°C.
Storage: -55°C to +85°C.
Temperature Coefficient:
±0.03%/°C typical, ±0.05%/°C maximum over entire
operating temperature range of 0°C to +70°C.
Cooling:
Convection cooling is adequate for convection power ratings
providing that non-restricted convection air movement
is available. When operating in a confined area, forced air
cooling is recommended. See voltage / current rating charts
for individual model airflow requirements.
Vibration:
Random vibration from 10Hz to 2KHz, 6.15 grms (3 axis).
Shock:
Operating: 20G peak acceleration.
Safety Agency Certifications:
| Return to TOP |
| Normal Voltage |
Model | Convection Cooled Current |
Forced Air Current |
Initial Setting Tolerance |
Line Regulation |
Load Regulation |
Output Adjustmemt Range |
Configuration |
| 5V | BVS-030 S10052 |
6A/8Apk | N/A | 5.0V±.2% | 0.2% | 3% | 4.75V to 5.50V |
BOARD ONLY 5.00" x 3.00" x 1.17" (127mm) x (76.2mm) x (29.7mm) |
| BVS-040 S10051 |
8A/11Apk | N/A | 5.1V±.2% | 0.2% | 1% | 4.75V to 5.50V |
U-Channel Chassis 6.00" x 3.27" x 1.60" (152.4mm)x(83.06mm) x (40.64mm) |
|
| BVS-040 S10052 |
8A/11Apk | 11A | 5.0V±.2% | 0.2% | 1% | 4.75V to 5.50V |
BOARD ONLY 5.00" x 3.00" x 1.38" (127mm)x(76.2mm) x (35.1mm) |
|
| BVS-080 S10051 |
16A/18Apk | N/A | 5.1V±.2% | 0.2% | 1% | 4.75V to 5.50V |
U-Channel Chassis 7.20" x 4.20" x 1.80" (182.88mm) x (106.68mm)x(45.72mm) |
|
| 12V-15V Adjustable* |
BVS-040 S10122 |
3.4A 2.2A |
4.6A 3A |
12.0V±.2% | 0.2% | 1% | 11V to 18V |
BOARD ONLY 5.00" x 3.00" x 1.38" (127mm)x(76.2mm) x (35.1mm) |
| BVS-060 S10121 |
5A/5.8Apk 4A/4.7Apk |
N/A | 12.1V±.1% | 0.2% | 2% | 11V to 16V |
U-Channel Chassis 6.00" x 3.27" x 1.60" (152.4mm)x(83.06mm) x (40.64mm) |
|
| BVS-080 S10121 |
7.5A/9.2Apk 6A/7.3Apk |
N/A | 12.1V±.1% | 0.2% | 1% | 11V to 16V |
U-Channel Chassis 7.20" x 4.20" x 1.80" (182.88mm) x (106.68mm)x(45.72mm) |
|
| 24V-28V Adjustable* |
BVS-040 S10242 |
1.7A 1.4A |
2.3A 1.9A |
24.0V±.2% | 0.2% | 1% | 23V to 29V |
BOARD ONLY 5.00" x 3.00" x 1.38" (127mm)x(76.2mm) x (35.1mm) |
| BVS-060 S10241 |
2.5A/3Apk 2.2A/2.5Apk |
N/A | 24.0V±.2% | 0.2% | .5% | 23.5V to 29V |
U-Channel Chassis 6.00" x 3.27" x 1.60" (152.4mm)x(83.06mm) x (40.64mm) |
|
| BVS-080 S10241 |
3.8A/4.6Apk 3.2A/3.9Apk |
N/A | 24.0V±.2% | 0.2% | .5% | 23V to 29V |
U-Channel Chassis 7.20" x 4.20" x 1.80" (182.88mm)x (106.68mm)x(45.72mm) |
| Return to TOP |
| Power(Watts) | Model | Voltage | Current | Initial Setting Tolerance |
Line Regulation |
Load Regulation |
Configuration | |
| Continuous | Peak | |||||||
| 50 | 55 | BVS-050 M20012 |
+12V | 2.1A/2.3A PK | Adjustable 10.8 to 13.2V |
0.2% | 2% | BOARD ONLY 7.00" x 2.00" x 1.25" (177.8mm) x (50.8mm) x (31.8mm) |
| -12V | 2.1A/2.3A PK | ±4% Note C |
0.5% | 2% | ||||
| 55 | 65 | BVS-060 M40001 |
+5V | 6A | Adjustable Note A |
0.2% | 2% | U-Channel Chassis 6.00" x 3.27" x 1.60" (152.4mm)x (83.06mm)x(40.64mm) |
| +12V | 3A/4A PK | ±4% Note C |
0.2% | 2% | ||||
| -5V | 0.5A Note F |
±4% Note C |
0.5% | 2% | ||||
| -12V | 0.5A Note F |
±4% Note C |
0.5% | 2% | ||||
| 55 | 65 | BVS-060 M40011 |
+5V | 6A | Adjustable Note A |
0.2% | 2% | U-Channel Chassis 6.00" x 3.27" x 1.60" (152.4mm)x (83.06mm)x(40.64mm) |
| +24V | 1.5A/2.5A PK | ±4% Note C |
0.2% | 2% | ||||
| -12V | 0.5A Note F |
±4% Note C |
0.5% | 2% | ||||
| +12V | 0.5A Note F |
±4% Note C |
0.5% | 2% | ||||
| 55 | 65 | BVS-060 M40021 |
+5V | 6A | Adjustable Note A |
0.2% | 2% | U-Channel Chassis 6.00" x 3.27" x 1.60" (152.4mm)x (83.06mm)x(40.64mm) |
| +12V | 3A/4A PK | ±4% Note C |
0.2% | 2% | ||||
| -12V | 0.5A Note F |
±4% Note C |
0.5% | 2% | ||||
| +12V | 0.5A Note F |
±4% Note C |
0.5% | 2% | ||||
| 55 | 65 | BVS-060 M40021 |
+5V | 6A | Adjustable Note A |
0.2% | 2% | U-Channel Chassis 6.00" x 3.27" x 1.60" (152.4mm)x (83.06mm)x(40.64mm) |
| +15V | 2.5A/3.5A PK | ±4% Note C |
0.2% | 2% | ||||
| -5V | 0.5A Note F |
±4% Note C |
0.5% | 2% | ||||
| -15V | 0.5A Note F |
±4% Note C |
0.5% | 2% | ||||
| 55 | 65 | BVS-060 M40041 |
+5V | 6A | Adjustable Note A |
0.2% | 2% | U-Channel Chassis 6.00" x 3.27" x 1.60" (152.4mm)x (83.06mm)x(40.64mm) |
| +24V | 1.5A/2.5A PK | ±4% Note C |
0.2% | 2% | ||||
| -15V | 0.5A Note F |
±4% Note C |
0.5% | 2% | ||||
| +15V | 0.5A Note F |
±4% Note C |
0.5% | 2% | ||||
| 80 | 90 | BVS-080 M40001 |
+5V | 14A | Adjustable Note A |
0.2% | 1% | U-Channel Chassis 7.20" x 4.20" x 1.80" (182.88mm)x (106.68mm)x(45.72mm) |
| +12V | 4A/7A PK | Adjustable Note B |
0.2% | 1% | ||||
| -5V | 1A | ±4% Note C |
0.5% | 2% | ||||
| +12V | 1A | ±4% Note C |
0.5% | 2% | ||||
| 80 | 90 | BVS-080 M40011 |
+5V | 14A | Adjustable Note A |
0.2% | 1% | U-Channel Chassis 7.20" x 4.20" x 1.80" (182.88mm)x (106.68mm)x(45.72mm) |
| +24V | 2A/3.5A PK | Adjustable Note B |
0.2% | 1% | ||||
| -12V | 1A | ±4% Note C |
0.5% | 2% | ||||
| +12V | 1A | ±4% Note C |
0.5% | 2% | ||||
| 80 | 90 | BVS-080 M40021 |
+5V | 14A | Adjustable Note A |
0.2% | 1% | U-Channel Chassis 7.20" x 4.20" x 1.80" (182.88mm)x (106.68mm)x(45.72mm) |
| +12V | 4A/7A PK | Adjustable Note B |
0.2% | 1% | ||||
| -12V | 1A | ±4% Note C |
0.5% | 2% | ||||
| +12V | 1A | ±4% Note C |
0.5% | 2% | ||||
| 80 | 90 | BVS-080 M40031 |
+5V | 14A | Adjustable Note A |
0.2% | 1% | U-Channel Chassis 7.20" x 4.20" x 1.80" (182.88mm)x (106.68mm)x(45.72mm) |
| +15V | 3.5A/6A PK | Adjustable Note B |
0.2% | 1% | ||||
| -5V | 1A | ±4% Note C |
0.5% | 2% | ||||
| -15V | 1A | ±4% Note C |
0.5% | 2% | ||||
| 80 | 90 | BVS-080 M40041 |
+5V | 14A | Adjustable Note A |
0.2% | 1% | U-Channel Chassis 7.20" x 4.20" x 1.80" (182.88mm)x (106.68mm)x(45.72mm) |
| +24V | 2A/3.5A PK | Adjustable Note B |
0.2% | 1% | ||||
| -15V | 1A | ±4% Note C |
0.5% | 2% | ||||
| +15V | 1A | ±4% Note C |
0.5% | 2% | ||||
| 80 | 90 | BVS-080 M41001 |
+5V | 14A | Adjustable Note A |
0.2% | 1% | U-Channel Chassis 7.20" x 4.20" x 1.80" (182.88mm)x (106.68mm)x(45.72mm) |
| +12V | 4A/7A PK | Adjustable Note B |
0.2% | 1% | ||||
| -5V | 1A | ±4% Note C |
0.5% | 2% | ||||
| -12V | 3A | ±4% Note C |
0.5% | 2% | ||||
| 80 | 90 | BVS-080 M42001 |
+5V | 14A | Adjustable Note A |
0.2% | 1% | U-Channel Chassis 7.20" x 4.20" x 1.80" (182.88mm)x (106.68mm)x(45.72mm) |
| +12V | 4A/7A PK | Adjustable Note B |
0.2% | 1% | ||||
| -12V | 1A | ±4% Note C |
0.5% | 2% | ||||
| -5V | 3A | ±4% Note C |
0.5% | 2% | ||||
| 100 | 113 | BVS-100 EG03 |
+6.5V | 9.6A/10A PK | Adjustable 6.2V to 6.8V |
0.2% | 1% | BOARD ONLY 9.00" x 2.20" x 1.55" (228.6mm)x(55.8mm) x(39.4mm) |
| +12V | 1.6A/2A PK | ±4% Note C |
0.5% | 2% | ||||
| -12V | 1.6A/2A PK | ±4% Note C |
0.5% | 2% | ||||
| 180 | 180 | BVS-180 M20011 |
+5V | 12A | Adjustable Note A |
0.2% | 1% | U-Channel Chassis 5.50" x 5.00" x 1.65" (139.7mm)x(127.0mm) x(41.9mm) |
| +12V | 10A | Adjustable Note B |
0.2% | 1% | ||||
Notes: A. Voltage level adjustable from 4.75V to 5.50V. B. Full regulated output, voltage adjustable ±4% minimum. Factory set to ±1% of nominal. C. Fully regulated output, voltage fixed. D. Voltage level adjustable from 10V to 16V. Factory set to 12V ±0.2V. E. Quasi regulated output. See regulation curves at the end of this section. F. Max load on V3 or V4 can be 1 amp if either V3 or V4 is unloaded.
Custom variations are quoted and shipped promptly. |
| Return to TOP |
|
We continually improve our products, therefore
specifications are subject to change without notice.
PowerVolt does not assume liability arrising out of
use or misuse of any product.
PowerVolt does not recommend the use of its products
in applications wherin a failure or malfunction
may directly threaten life or cause human injury.
The user of PowerVolt products assumes all risk of such use
and indemnifies PowerVolt against all damages. |
| Return to TOP |