FlatZtran
Low Profile Printed Circuit Power Transformer
Series: FZ-24
Standard Models
Schematic
Dimensions
Cross reference
|
- Single Primary - 24V, 50/60Hz
- Low profile - 0.65" for 2.5VA for 6VA, 1.06" for 12VA
- Non-concentric windings, low capacitive coupling,
no electrostatic shield needed
- Hum-bucking semi-toroidal construction;
balanced windings and reduced radiated magnetic field
- Class B insulation - 130°C
- 1500Vrms hipot
- Applications include HVAC-R Instrumentation and low-input voltage
-
Designed to meet UL/CSA
|
The FlatZtran with its non-concentric windings provides high isolation.
The semi-toroidal construction reduces the radiated magnetic field and humming.
1500Vrms hipot is standard.
Applications
The FlatZtran is ideal for height critical PC board designs.
Applications include:
- On-board DC power supplies, single or dual outputs
- Isolated control circuits
- Reference power supplies
- Semiconductor control and instrumentation
- Low input voltage (e.g. 24V, custom 12V input also available)
- HVAC-R
instrumentation
- Low voltage/high isolation circuits (e.g. power supplies)
Schematic
Mechanical Drawings
Dimensions
| Size | L | W | H | A | B | C | D |   Oz  
|
|---|
| 2 |   1.87   |   1.56   |   0.650   |   1.600  
|   0.375   |   0.375   |   .041 x .020   |   5  
|
| 6 | 1.87 | 1.56 | 0.850 | 1.600 | 0.375 | 0.375 | .041 x .020 | 7
|
|   12   | 2.50 | 2.00 | 1.065 | 2.000 | 0.500 | 0.500 | .041 x .020 | 11
|
| 24 | 2.87 | 2.23 | 1.250 | 1.90 | 0.600 | 0.530 | .041(sq.pin) | 15
|
|   48   | 3.12 | 2.50 | 1.375 | 2.180 | 0.600 | 0.660 | .041(sq.pin) | 21
|
Standard Models
Voltage Selection Guide:
10volts
12volts
16volts
20volts
24volts
30volts
34volts
40volts
56volts
88volts
120volts
230volts
We continually improve our products, therefore
specifications are subject to change without notice.
PowerVolt does not assume liability arising out of
use or misuse of any product.
PowerVolt does not recommend the use of its products
in applications wherein a failure or malfunction
may directly threaten life or cause human injury.
The user of PowerVolt products assumes all risk of such use
and indemnifies PowerVolt against all damages.
|