| Back to Transformers Index | Home | Contact Us |
Standard Models   Schematics Dimensions
![]() |
|
| Return to TOP |
![]() |
Primaries are designed to be used simultaneously. That is, they must be used either Series or Parallel connected (as one winding). Same applies to secondaries also. |
| Return to TOP |

Dimensions
| DIMENSIONS | SQPin Dim. |
MTG.DIM. | Mtg Screw |
WGT | ||||||||||
| (VA) Size |
L | W | H | A | B | C | D | M | N | P | Size | Qty. | ||
| 20 | 2.25" 57.2mm |
1.87" 47.6mm |
1.62" 41.3mm |
0.400" 10.2mm |
0.400" 10.2mm |
1.460" 37.1mm |
0.200" 5.1mm |
0.038" 0.97mm |
1.50" 38.1mm |
- - |
- - |
#4 | 2 | 0.90lbs 0.41kg |
| 30 | 2.62" 66.7mm |
2.18" 55.5mm |
1.56" 39.7mm |
0.550" 13.9mm |
0.275" 7.0mm |
1.680" 42.7mm |
0.275" 7.0mm |
0.045" 1.14mm |
- - |
1.75" 44.5mm |
2.18" 55.4mm |
#6 | 4 | 1.15lbs 0.52kg |
| 50 | 3.00" 76.2mm |
2.50" 63.5mm |
1.81" 46.0mm |
0.600" 15.2mm |
0.300" 7.6mm |
1.900" 48.3mm |
0.300" 7.6mm |
0.045" 1.14mm |
- - |
2.00" 50.8mm |
2.50" 63.5mm |
#6 | 4 | 1.70lbs 0.77kg |
| Return to TOP |
Voltage Selection Guide:
10volts
12volts
16volts
20volts
24volts
28volts
36volts
| Part Number | VA (Size) | Secondery RMS Rating | ||
| Series | Parallel | |||
| Series: 10 Volts and Parallel: 5 Volts Back | ||||
|---|---|---|---|---|
| 14P-20-10 | 20 | 10VCT @ 2.0A | 5V @ 4.0A | |
| 14P-30-10 | 30 | 10VCT @ 3.0A | 5V @ 6.00A | |
| 14P-56-10 | 56 | 10VCT @ 5.6A | 5V @ 11.2A | |
| Series: 12.6 Volts and Parallel: 6.3 Volts Back | ||||
| 14P-20-12 | 20 | 12.6VCT @ 1.6A | 6.3V @ 3.2A | |
| 14P-30-12 | 30 | 12.6VCT @ 2.4A | 6.3V @ 4.8A | |
| 14P-56-12 | 56 | 12.6VCT @ 4.4A | 6.3V @ 8.8A | |
| Series: 16 Volts and Parallel: 8 Volts Back | ||||
| 14P-20-16 | 20 | 16VCT @ 1.25A | 8V @ 2.5A | |
| 14P-30-16 | 30 | 16VCT @ 1.90A | 8V @ 3.8A | |
| 14P-56-16 | 56 | 16VCT @ 3.50A | 8V @ 7.0A | |
| Series: 20 Volts and Parallel: 10 Volts Back | ||||
| 14P-20-20 | 20 | 20VCT @ 1.0A | 10V @ 2.0A | |
| 14P-30-20 | 30 | 20VCT @ 1.5A | 10V @ 3.0A | |
| 14P-56-20 | 56 | 20VCT @ 2.8A | 10V @ 5.6A | |
| Series: 24 Volts and Parallel: 12 Volts Back | ||||
| 14P-20-24 | 20 | 24VCT @ 0.83A | 12V @ 1.66A | |
| 14P-30-24 | 30 | 24VCT @ 1.25A | 12V @ 2.50A | |
| 14P-56-24 | 56 | 24VCT @ 2.33A | 12V @ 4.66A | |
| Series: 28 Volts and Parallel: 14 Volts Back | ||||
| 14P-20-28 | 20 | 28VCT @ 0.72A | 14V @ 1.44A | |
| 14P-30-28 | 30 | 28VCT @ 1.06A | 14V @ 2.12A | |
| 14P-56-28 | 56 | 28VCT @ 2.00A | 14V @ 4.00A | |
| Series: 36 Volts and Parallel: 18 Volts Back | ||||
| 14P-20-36 | 20 | 36VCT @ 0.56A | 18V @ 1.12A | |
| 14P-30-36 | 30 | 36VCT @ 0.82A | 18V @ 1.64A | |
| 14P-56-36 | 56 | 36VCT @ 1.56A | 18V @ 3.12A | |
|
Custom variations are quoted and shipped promptly. | ||||
|
We continually improve our products, therefore
specifications are subject to change without notice.
PowerVolt does not assume liability arrising out of
use or misuse of any product.
PowerVolt does not recommend the use of its products
in applications wherin a failure or malfunction
may directly threaten life or cause human injury.
The user of PowerVolt products assumes all risk of such use
and indemnifies PowerVolt against all damages. |
| Return to TOP |